DESIGN SERVICES
Radiant Circuit (loop) Layout design services.
Our HRAI (the Heating, Refrigeration and Air Conditioning Institute of Canada) certified staff-designer will work with you
and provide adaptation of our Modular Zone Panels to your available system
design.This service is free with purchase of a complete packaged zone panel.We also can
provide design of Radiant Circuit (loop) Layout, Heat Loss calculations, and Mechanical
Room Layout. There will be no difference from packages you are getting from
other suppliers; these paid services are available as per below listed items.
We also offer a complete design packages that includes:
- 11 x 17 sheets showing plan view of tubing layout including locations of manifolds, heat source and components.
- Complete system diagram utilizing Modular Hydronics Zone Panels including specifications on circulators, manifolds, expansion tank, heat sources and sizing of distribution piping.
- Control wiring diagram providing control schematics.
Our designs conform
to both ASHRAE and CSA residential heat loss calculation standards and
HRAI guidelines for the design and installation of radiant heating systems.
Please supply architectural floor plans in (PDF, AutoCAD, JPG) format. A separate file must be provided for each floor of the building. Indicate proposed locations for manifolds, mechanical room and any known obstacles. Loop layout makes it easy to professionally install radiant tubing.